Naresuan University and the UK's Cranfield University have deployed real-time sensor stations on the Sai and Kok Rivers in Chiang Rai to monitor lead contamination. The sensors feed a Digital Twin platform that uses AI and two years of historical data to model pollution risks, though accuracy is currently limited. Authorities plan to expand the network across the border with Myanmar for earlier warnings.
Naresuan University has partnered with the UK's Cranfield University to install sensors that monitor lead contamination in the Sai River in real time. The devices measure turbidity and dissolved oxygen, transmitting processed data every 15 minutes.
November 28, 2026 – Naresuan University, together with Cranfield University (UK) and the Office of the Permanent Secretary of the Ministry of Higher Education, Science, Research and Innovation, went into the field in Mae Sai District, Chiang Rai, to install and demonstrate a sensor station for water quality monitoring and real-time lead surveillance in the Sai River.
Assoc. Prof. Dr. Thanapol Penrat, a lecturer in the Department of Civil Engineering, Environmental Engineering program, Faculty of Engineering, Naresuan University, disclosed that the sensor station will measure turbidity, electrical conductivity, temperature, ORP, and dissolved oxygen, sending processed data every 15 minutes. Meanwhile, the station on the Kok River transmits data every three minutes before feeding it into a Digital Twin system. That system uses nearly two years of accumulated water and sediment test results, combined with statistical techniques and AI, to assess the relationship between turbidity, electrical conductivity, and the quantity of lead and sediment contaminants in suspended solids, because there is currently no sensor that can directly and efficiently detect those heavy metals.
The system can simulate the movement of water and sediment without requiring sensors along the entire river course, and can evaluate risk in downstream areas. However, in the initial phase the model's accuracy is only about 30–50%, so the model must be calibrated and data continuously accumulated, while adopting preventive alert thresholds. If a risk is detected, the public should avoid using the water temporarily until government laboratory results confirm safety.
The public can access data via the Digital Twin website, which displays the situation by sub-district and district levels and assesses water suitability for consumption, agriculture, washing, and recreation, benchmarked against Department of Health standards. Chiang Rai Province can also use the data for daily risk monitoring and reporting, and to alert the governor to issue public warnings.
The next phase aims to link sensor data from the Myanmar side, allowing detection of water and sediment anomalies several hours before they enter Thailand.